Description
• Fast-acting
• Optional axial leads available
• 1⁄4˝ x 1 1⁄4˝ (6.4 x 31.7mm) physical size
• Ceramic tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
Electrical Characteristics | |
% of Amp Rating | Opening Time |
100% | 4 Hours Minimum |
135% | 60 Minutes maximum |
200% | 60 Minutes maximum |
Dimensions - mm (in)
Agency Information
• UL Listed: Guide JDYX & File E19180.
• UL Recognition: Guide JDYX2 & File E19180.
• CSA Certification: Class 1422-01 & 1422-03, File 53787.
Environmental Data
• Shock: 1⁄4-30A – MIL-STD-202, Method 213, Test Condition J
• Vibration: 1⁄4-30A – MIL-STD-202, Method 204, Test Condition C (Except 5g, 500HZ)
Ordering
• Specify packaging, product, and option code
Part Number | Voltage Ratings | Vac Interrupting Ratings*(amps) | Vdc Interrupting Ratings (amps) | Typical DC Cold Resistance(Ω)** | Typical Pre-Arc I2t AC† | Typical Voltage Drop(mV)‡ | Agency Approvals | ||
250 | 125 | 125 | 75 | ||||||
ABC-1/4-R | 250Vac,125Vdc | 35 | 10000 | 10000 | 2.95 | 0.002 | 0.35 | UL,CSA | |
ABC-1/2-R | 0.587 | 0.039 | 0.41 | UL,CSA | |||||
ABC-3/4-R | 0.3 | 0.145 | 0.32 | UL,CSA | |||||
ABC-1-R | 0.195 | 0.431 | 0.3 | UL,CSA | |||||
ABC-1-1/2-R | 100 | 0.131 | 1.163 | 0.28 | UL,CSA | ||||
ABC-2-R | 0.089 | 2.167 | 0.31 | UL,CSA | |||||
ABC-2-1/2-R | 0.061 | 4.467 | 0.23 | UL,CSA | |||||
ABC-3-R | 0.047 | 6.55 | 0.14 | UL,CSA | |||||
ABC-4-R | 200 | 0.031 | 22.28 | 0.17 | UL,CSA | ||||
ABC-5-R | 0.026 | 32.83 | 0.22 | UL,CSA | |||||
ABC-6-R | 0.021 | 58 | 0.19 | UL,CSA | |||||
ABC-7-R | 0.016 | 109.33 | 0.17 | UL,CSA | |||||
ABC-8-R | 0.014 | 116.5 | 0.19 | UL,CSA | |||||
ABC-10-R | 0.011 | 208.8 | 0.15 | UL,CSA | |||||
ABC-12-R | 750 | 0.0068 | 133.3 | 0.1 | UL,CSA | ||||
ABC-15-R | 0.00553 | 200.2 | 0.1 | UL,CSA | |||||
ABC-18-R | 250Vac | 400 | 1000 | 0.00465 | 400 | 0.1 | UR,CSA | ||
ABC-20-R | 250Vac,125Vdc | 10000 | 0.00366 | 550.8 | 0.1 | UR,CSA | |||
ABC-25-R | 200 | 400 | 1000 | 0.0028 | 839.3 | 0.09 | UR,CSA‡‡ | ||
ABC-30-R | 0.002225 | 1429 | 0.09 | UR,CSA‡‡ |
** Typical DC cold resistance measured at <10% of rated current.
† Typical melting I2t measured at listed interrupting rating and rated voltage.
‡ Typical voltage drop measured at 25°C±3°C ambient temperature at rated current.
‡‡ CSA approvals for 25A and 30A are at 125Vac - IR 1000A and 125Vdc - IR 400A (IR 1000A at 75Vdc)
Time-Current Curve
Packaging Code | Description |
BK | 100 fuses packed into a cardboard carton |
BK1 | 1000 fuses packed into a cardboard carton |
BK8 | 8000 fuses packed into a cardboard carton |
Option Code | Description |
V | Axial leads - copper tinned wire with nickel plated brass overcaps.eg.ABC-V-20-R |