cooper bussmann

GBB Series 1/4" x 1 1/4" Very Fast-Acting Ceramic Tube Fuses

  
Description
• Very fast-acting
• Optional axial leads available
• 1⁄4" x 1 1⁄4" (6.3 x 32mm) physical size
• Ceramic tube, nickel-plated brass endcap construction
• 100pc-carton quantity weighs 1.0 lb (0.45 kg)
• UL Recognized product meets standard 248-14

Electrical Characteristics
Rated Current % of Amp Rating Opening Time
1A - 20A 100% None
150% 2 minutes maximum
250% 1 seconds maximum
400% -
25A, 30A 100% None
150% 2 minutes maximum
250% 6 seconds maximum
400% -


Agency Information
• UL Recognized Card: 1-30A (JFHR2, E56412)
• CSA Component Accepted Card: 1-30A (Class 1422-30 File 53787)

Ordering
• Specify packaging, product, and option code

Dimensions - mm/in

Specifications
Part Number Voltage Rating AC Interrupting Rating (amps)* DC Interrupting Rating (amps)* 125Vdc Typical DC Cold Resistance (Ω)** Typical Voltage Drop (V)‡
Vac Vdc 250Vac 125Vac
GBB-1-R 250 125 200 10,000 10,000 0.1775 0.2096
GBB-1-1/4-R 250 125 200 10,000 10,000 0.179 0.2497
GBB-2-R 250 125 200 10,000 10,000 0.0662 0.1687
GBB-3-R 250 125 200 10,000 10,000 0.04475 0.1816
GBB-4-R 250 125 200 10,000 10,000 0.03175 0.1778
GBB-5-R 250 125 200 10,000 10,000 0.02125 0.1217
GBB-6-R 250 125 200 10,000 10,000 0.018 0.1324
GBB-7-R 250 125 200 10,000 10,000 0.0155 0.1355
GBB-8-R 250 125 200 10,000 10,000 0.0136 0.1144
GBB-9-R 250 125 200 10,000 10,000 0.0107 0.1218
GBB-10-R 250 125 200 10,000 10,000 0.00934 0.0877
GBB-12-R 250 125 200 10,000 10,000 0.0062 0.0806
GBB-15-R 250 125 200 10,000 10,000 0.00472 0.0735
GBB-20-R 250 125 200 200 200 0.0033 0.0728
GBB-25-R 250 125 200 200 200 0.00252 0.061
GBB-30-R 250 125 200 200 200 0.00206 0.0657

* Interrupting ratings: Interrupting ratings for 1-15A at 125Vdc was measured at 10,000A, 3.5 ms maximum, with time constant. Ratings 20-30A at 125Vdc were measured at 200A, 0.5 ms maximum, with time constant. Ratings 1-15A at 125Vac were measured at 10,000A, and 70% - 80% power factor. The interrupting ratings for 1-30A at 250Vac were measured at 90% - 100% power factor.
** DC Cold Resistance (Measured at <10% of rated current)
† Typical Melting I2t (I2t was measured at listed interrupting rating and rated voltage) Interrupting ratings were measured at 70% to 80% power factor on AC.
‡ Typical Voltage drop (Voltage drop was measured at 25°C±3°C ambient temperature at rated current)

Time-Current Curve


Packaging
Packaging Code Description
BK 100 fuses packed into a cardboard carton
BK1 1,000 fuses packed into a cardboard carton


Option Code
Option Code Description
B Sealed to withstand aqueous cleaning (board washable)