cooper bussmann

B22 Series A/C Disconnects - Fused and Non-fused

  
Description:
Fused and non-fused rainproof air conditioner pullout units.

Construction: NEMA 3R rainproof metal housing with weather resistant coating.
Wire Range: 14-3 AWG, Al/Cu

Ratings:
Phase: Single, 2-wire
Volts: 240Vac
Amps: 30-60A
Agency Information: UL Listed to UL 1429, C-UL Certified, UL Guide WGEW

Features and Benefits
• A/C disconnects meet NEC® Code Requirements under articles 440.14. GFCI units meet NEC® Code Requirements under articles 210.63, 210.8, and 406.8(B)(1).
• NEMA 3R rainproof enclosures withstand outdoor environment.
• Padlockable with two-position pullout handle to lock safety shield when in the ON position. (Not available on GF or NA units.) For added safety, pullout handle can be stored in the compartment in the off position.

Typical Applications
• Residential, light industrial/commercial A/C and heat pump service.
• Spas/whirlpools, swimming pools, pump houses
• Suitable for service entrance equipment applications with field installable ground bar, kit number DPFG.



Metallic Fused Disconnect


Metallic Non-Fused Disconnect


Metallic Non-Fused Disconnect with Weather Resistant- Tamper Resistant GFCI Receptacle.


B222-60NF34W non-fused with cable whip

Catalog Number Description Disconnect Rating Max Hp Rating Wire Range 60 or 75℃ CU/AL Enclosure Type Fuse Class Approx. Dimensions(in)
120V 240V Height Width Depth
FUSED
B221-30F 30A, Pullout 30A 1.5 3 #14-3 NEMA 3R H or R 8 3/4 5 3/8 2 7/8
B221-30FGF 30A, Pullout w/ GFCI 13 7 1/2 4 3/4
B221-30FGFWRTR 30A, Pullout W/ WRTR-Rated GFCI
B222-60F 60A, Pullout 60A 3 10 8 3/4 5 3/8 2 7/8
B222-60FGF 60A, Pullout w/ GFCI 13 7 1/2 4 3/4
B221-60FGFWRTR 60A, Pullout W/ WRTR-Rated GFCI
NON-FUSED
B222-60NF 60A, Pullout 60A 3 10 #14-3 NEMA 3R * 8 3/4 5 3/8 2 7/8
B222-60NFGF 60A, Pullout w/ GFCI 11 3/4 6 1/2 4 1/2
B222-60NFGFWRTR 60A, Pullout W/ WRTR-Rated GFCI
B222-60NFNA 60A, Switch * 8 3/4 5 3/8 3 5/8
NON-FUSED CABLE WHIP
B222-60NF12W 60A, Pullout w/ 1/2" Cable Whip 60A* 3 10 #14-3 NEMA 3R * 14 3/4 12 1/2 4
B222-60NF34W 60A, Pullout w/ 3/4" Cable Whip 60A**


Cable Whip Specifications
Catalog Numbers Description Pullout Rating Max UpstreamWire Overcurrent Protection Device Harness Diameter Ground Hot Wire Size Flexible Wire Size Conduit Length (ft) Non-Metallic Fittings
B222-60NF12W 60A, Pullout w/ 1.2" Cable Whip 60A 30A 1.2" #10 #10 6 1 - 90°, 1 - Straight
B222-60NF34W 60A, Pullout w/ 3.4" Cable Whip 60A 50A 3.4"  #8 #10 6 1 - 90°, 1 - Straight

* Upstream overcurrent protection device (OCPD) not to exceed 30 Amps.
**Upstream overcurrent protection device (OCPD) not to exceed 50 Amps.
30 and 60A pullout replacement handle: 96-3258-4.
----------------------------------