• Axial-leaded time-delay thru-hole fuse
• Matte tin-plated copper lead wires
• High temperature epoxy plastic body, UL 94V0
Agency Information
• UL Recognition Guide & File numbers: JDYX2 & E195337.
• CSA Certification Record No: LR 701159 & Class No: 1422 30 and 1422 01.
Environmental Data
• Shock resistance: MIL-STD-202, Method 213B, Test Condition I (Sawtooth)
• Vibration resistance: MIL-STD-202, Method 201 (10-55Hz x 3 axis/ no load)
• Moisture resistance: MIL-STD-202F, Method 106
• Soldering heat resistance: MIL-STD-202, Method 210 Top side (260ºC, 20 sec)
• Salt spray: MIL-STD-202, Method 101, Test Condition B (48 Hours)
• Solderability MIL-STD-202, Method 208H
• Operating Temperating: -55ºC to 125ºC
Ordering
Specify packaging
• Insert packaging code prefix before part number. E.g., TR1 (or BK1)/MCRS5A
Dimensions - mm (in)
Specifications | ||||||
Part Number | Voltage Rating Vac/dc | Interrupting Rating* (amps) | Resistance (Ω)** Typical | Typical Melt I2t† | Typical Voltage Drop‡ | |
Vac | Vdc | |||||
MCRS250mA | 125 | 50 | 300 | 3.2 | 0.042 | 2.2 |
MCRS300mA | 125 | 50 | 300 | 2.57 | 0.056 | 2.02 |
MCRS375mA | 125 | 50 | 300 | 1.66 | 0.101 | 1.69 |
MCRS500mA | 125 | 50 | 300 | 1.07 | 0.18 | 1.42 |
MCRS750mA | 125 | 50 | 300 | 0.55 | 0.44 | 1.09 |
MCRS1A | 125 | 50 | 300 | 0.36 | 0.78 | 0.91 |
MCRS1.25A | 125 | 50 | 300 | 0.23 | 1.41 | 0.77 |
MCRS1.5A | 125 | 50 | 300 | 0.18 | 1.9 | 0.7 |
MCRS2A | 125 | 50 | 300 | 0.12 | 3.4 | 0.59 |
MCRS2.5A | 125 | 50 | 300 | 0.08 | 6.1 | 0.5 |
MCRS3A | 125 | 50 | 300 | 0.06 | 8.1 | 0.45 |
MCRS4A | 125 | 50 | 300 | 0.04 | 15 | 0.38 |
MCRS5A | 125 | 50 | 300 | 0.02 | 35 | 0.29 |
MCRS7A | 125 | 50 | 300 | 0.01 | 63 | 0.25 |
* AC Interrupting Rating (Measured at designated voltage, 100%) DC Interrupting Rating (Measured at designated voltage, rise time of less than 50 microseconds, battery source)
** DC Cold Resistance (Measured at 10% of rated current)
† Typical Melting I2t (Measured with a battery bank at rated DC voltage, 10x-rated current, rise time of calibrated circuit less than 50 microseconds)
‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes)
Time-Current Curve
Packaging Code | |
Packaging Code Prefix | Description |
BK1 | 1,000 fuses in bulk |
TR1 | 2,500 fuses on tape-and-reel per EIA-296-F @ 5mm pitch and 52.4mm inside tape spacing |