Description
• Time-delay
• Optional axial leads available
• 1/4˝ x 1-1/4˝ (6.35 x 31.75mm) physical size
• Ceramic tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
Electrical Characteristics
Rated Current | Amp Rating | Opening Time |
1/4 - 30A | 100% | None |
135% | 60 Minutes Max. | |
200% | 120 Seconds Max. |
Agency Information
• UL Listed Card: MDA 2/10 - 20A (Guide JDYX, File E19180)
• UL Recognized Card: MDA 25 - 30A (Guide JDYX2, File E19180)
• CSA Certification Card: MDA 2/10 - 20 (Class No. 1422-01)
• CSA Component Acceptance: MDA 25-30A (Class No. 1422-30)
Environmental Data
• Shock: 1/100A and 8/10A – MIL-STD-202, Method 213, Test Condition I; 1A thru 30A – MIL-STD-202, Method 213, Test Condition J
• Vibration: 1/100A and 8/10A – MIL-STD-202, Method 201; 1/4A thru 30A – MIL-STD-202, Method 204, Test Condition C (Except 5g, 500HZ)
Ordering
• Specify packaging, product, and option code
Dimensions - mm (in)
Drawing Not to Scale
SPECIFICATIONS
Part Number | Voltage Rating | AC Interrupting Rating* (amps) | DC Interrupting Rating (amps) | Typical DC Cold Resistance** (Ω) | Typical Melting I2t† AC | Typical Voltage Drop‡ | ||
Vac | Vdc | 250V | 125V | 125V | ||||
MDA-1/4-R | 250 | - | 35 | 10000 | - | 9.325 | 0.748 | 4 |
MDA-1/2-R | 1.925 | 2.53 | 1.42 | |||||
MDA-3/4-R | 0.8555 | 8.58 | 1.31 | |||||
MDA-1-R | 0.56 | 12.21 | 1.03 | |||||
MDA-1-1/2-R | 100 | 0.2585 | 27.5 | 0.691 | ||||
MDA-2-R | 0.17 | 70.4 | 0.623 | |||||
MDA-2-1/2-R | 200 | 0.06685 | 31.79 | 0.213 | ||||
MDA-3-R | 0.0535 | 44.99 | 0.182 | |||||
MDA-4-R | 0.03625 | 147.4 | 0.162 | |||||
MDA-5-R | 0.0261 | 380.49 | 0.145 | |||||
MDA-6-R | 0.0212 | 587.73 | 0.141 | |||||
MDA-7-R | 0.0169 | 638.33 | 0.137 | |||||
MDA-8-R | 0.0135 | 1038.4 | 0.134 | |||||
MDA-10-R | 0.00948 | 1620.43 | 0.135 | |||||
MDA-12-R | 750 | 0.00725 | 125.18 | 0.128 | ||||
MDA-15-R | 0.00553 | 336.82 | 0.107 | |||||
MDA-20-R | 125 | 1500 | 10000 | 0.004 | 483.45 | 0.095 | ||
MDA-25A-R | 0.00305 | 734.69 | 0.105 | |||||
MDA-30A-R | 0.00243 | 1096.7 | 0.11 |
** DC Cold Resistance (Measured at ≤10% of rated current)
† Typical Melting I2t (A2Sec) (I2t was measured at listed interrupting rating and rated voltage)
‡ Typical Voltage Drop (Voltage drop was measured at 25°C ambient temperature at rated current)
Time-Current Curve
Packaging Code
Packaging Code | Description |
BK | 100 fuses packed into a cardboard carton |
BK1 | 1,000 fuses packed into a cardboard carton |
BK8 | 8,000 fuses packed into a cardboard carton |
Option Code
Option Code | Description |
B | Sealed to withstand aqueous cleaning (Board Washable) |
V | Axial leads - copper tinned wire with nickel plated brass overcaps |
总机: 0755-82862885, 82862629