Description
• Time-delay, surface mount fuse
• RoHS compliant, lead-free and halogen-free
• High inrush withstand capability
• Wire-in-Air performance
• Compatible with leaded and lead-free reflow and wave solder
Agency Information
• UR(UL) Recognition File number: E19180
Environmental Data
• Operating temperture range: -55°C to 125°C with proper derating
• Vibration: MIL-STD-202, Method 204 Condition D
• Solderability: ANSI/J-STD-002C, Test B
Ordering
• Specify packaging and product code
(i.e., TR/3216TD1-R)
Soldering Method
• Wave immersion: 260°C, 10 Sec. max.
• Infrared reflow: 260°C, 30 Sec. max.
• Hand solder: 350°C, 3 Sec. max.
Time-Current Curves
Dimensions - mm (in)
Drawing Not to Scale
Electrical Characteristics
Specifications
Electrical Characteristics
% of Amp Rating | Opening Time |
100% | 4 Hours Minimum |
200% | 1 Sec. Minimum, 120 Sec. Maximum |
300% | 0.05 Sec. Minimum, 3 Sec. Maximum |
800% | 0.002 Sec. Minimum, 0.05 Sec. Maximum |
Specifications
Product Code |
Current Rating Amps |
Voltage Rating |
Interrupting Rating (Amps)* |
Typical Resistance (Ω)** |
Typical Melt I2t† DC |
Typical Voltage Drop (mV)‡ |
||
Vac | Vdc | AC | DC | |||||
3216TD6.3-R | 6.3A | 32 | 32 | 35 | 35 | 0.006 | 10.54 | 56 |
3216TD7-R | 7A | 32 | 32 | 35 | 35 | 0.006 | 12.03 | 64 |
3216TD8-R | 8A | 32 | 32 | 35 | 35 | 0.0055 | 16.03 | 65 |
3216TD10-R | 10A | 32 | 32 | 35 | 35 | 0.0045 | 42.71 | 72 |
3216TD12-R | 12A | 32 | 32 | 35 | 35 | 0.00425 | 45.56 | 79 |
* AC Interrupting Rating (Measured at rated voltage with a unity power factor); DC Interrupting Rating (Measured at rated voltage, time constant of less than 50 microseconds, battery source)
** DC Cold Resistance (Measured at 10% of rated current)
† Typical Melting I2
t (Measured with a battery bank at rated DC voltage, 10x-rated current at 1 microsecond, not to exceed IR. Above 7A uses 70 micron thickness copper layer test board of IEC 60127-3.
Others uses 35 micron thickness copper layer.
‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes)
Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at elevated ambient temperatures.
Packaging
Packaging Code Prefix | Description |
TR | 2500 fuses on 12mm tape-and-reel on a 180mm reel per EIA-481-A & IEC286-3 |
总机: 0755-82862885, 82862629
传真: 总机 转 801
邮箱: service@bussmann.net.cn
网址: http://www.bussmann.net.cn
资料中心: http://bm-bussmann.com