* 6125FA Ratings above 2 amps are not recommended for new designs.
* Recommended replacement for 2A+ rating is the CB61F series.
Description
• Fast Acting Surface Mount Fuse
• Complies with the EIA-IS-722 Standard
• Solder Immersion Compatible
• Overcurrent protection of systems up to 125VAC/DC
• Wire-in-air design
ELECTRICAL CHARACTERISTICS
ELECTRICAL CHARACTERISTICS
% of Amp Rating | Opening Time |
100% | 4 Hours Minimum |
200% | 5 Seconds Maximum |
Agency Information
• UL Listed Guide and File Numbers (250mA-12A):JDYX & E19180
• UL Recognized Guide and File Numbers (15A):JDYX2 & E195337
• CSA Component Acceptance: 053787 C 000 & Class No: 1422 30
Environmental Data
• Shock: MIL-STD-202, Method 213, Test Condition 1(100 G’s peak for 6 milliseconds)
• Vibration: MIL-STD-202, Method 201 (10-55 Hz, 0.06inch, total excursion)
• Salt Spray: MIL-STD-202, Method 101, Test ConditionB (48 hrs)
• Insulation Resistance: MIL-STD-202, Method 302, TestCondition A (After Opening) 10,000 ohms minimum
• Resistance to Solder Heat: MIL-STD-202, Method 210,Test Condition F (20 sec, at 260° C)
• Thermal Shock: MIL-STD-202, Method 107, TestCondition B (-65° C to +125° C)
Ordering
• Specify product and packaging code
Dimensions mm⁄(inches)
Dimensions mm⁄(inches)
Soldering Method
• Wave Solder: 260°C, 10 sec max.(MIL-STD-202, Method 210)
• Infrared Reflow: 260°C, 30 sec max
SPECIFICATIONS
Product Code |
Voltage Rating AC DC DC |
Interrupting Rating* |
Resistance (ohms)** Typ. | Typical Melt I2t† | Typical Voltage Drop (V)‡ | ||||
125V AC | 125V DC | 86V DC | |||||||
6125FA250mA | 125V | 125V | 86V | 50A | 300A | 10,000A | 0.65 | 0.01 | 0.30 |
6125FA375mA | 125V | 125V | 86V | 50A | 300A | 10,000A | 0.36 | 0.03 | 0.25 |
6125FA500mA | 125V | 125V | 86V | 50A | 300A | 10,000A | 0.24 | 0.06 | 0.22 |
6125FA750mA | 125V | 125V | 86V | 50A | 300A | 10,000A | 0.15 | 0.07 | 0.17 |
6125FA1A | 125V | 125V | 86V | 50A | 300A | 10,000A | 0.11 | 0.14 | 0.17 |
6125FA1.25A | 125V | 125V | 86V | 50A | 300A | 10,000A | 0.09 | 0.24 | 0.16 |
6125FA1.5A | 125V | 125V | 86V | 50A | 300A | 10,000A | 0.07 | 0.41 | 0.15 |
6125FA2A | 125V | 125V | 86V | 50A | 300A | 10,000A | 0.05 | 0.80 | 0.15 |
6125FA2.5A | 125V | 125V | 86V | 50A | 300A | 10,000A | 0.038 | 1.4 | 0.14 |
6125FA3A | 125V | 125V | 86V | 50A | 300A | 10,000A | 0.028 | 2.4 | 0.13 |
6125FA3.5A | 125V | 125V | 86V | 50A | 300A | 10,000A | 0.025 | 3.3 | 0.13 |
6125FA4A | 125V | 125V | 86V | 50A | 300A | 10,000A | 0.022 | 4.4 | 0.13 |
6125FA5A | 125V | 125V | 86V | 50A | 300A | 10,000A | 0.016 | 7.8 | 0.12 |
6125FA6.3A | 125V | 125V | 86V | 50A | 300A | 10,000A | 0.012 | 14.0 | 0.12 |
6125FA7A | 125V | 125V | 86V | 50A | 300A | 10,000A | 0.011 | 19.0 | 0.114 |
6125FA10A | 125V | N/A | 86V | 50A | N/A | 10,000A | 0.007 | 44 | 0.107 |
6125FA12A | 125V | N/A | 86V | 50A | N/A | 10,000A | 0.006 | 69 | 0.103 |
6125FA15A | N/A | N/A | 86V | N/A | N/A | 10,000A | 0.004 | 124 | 0.098 |
* AC Interrupting Rating (Measured at designated voltage, 100% power factor); DC Interrupting Rating (Measured at designated voltage, time constant of less than 50
microseconds, battery source)
** DC Cold Resistance (Measured at 10% of rated current)
† Typical Melting I2
t (Measured with a battery bank at rated DC voltage, 10x-rated current, time constant of calibrated circuit less than 50 microseconds)
‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes)
Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at elevated ambient temperatures.
TIME CURRENT CURVE
PACKAGING CODE
Packaging Code | Description |
TR2 | 5,000 pieces of fuses on 12mm tape-and-reel on a 13 inch (330mm) reel per EIA Standard 481 |
总机: 0755-82862885, 82862629
传真: 总机 转 801
邮箱: service@bussmann.net.cn
网址: http://www.bussmann.net.cn