* 6125FF Ratings above 2 amps are not recommended for new designs.
* Recommended replacement for 2A+ rating is the CB61F series.
Description
• Fast-acting surface mount fuse
• Overcurrent protection of systems up to 125Vac/72Vdc
• High inrush withstand capability
• Solder immersion compatible
Electrical Characteristics
Electrical Characteristics
% of Amp Rating | Opening Time |
100% | 4 Hours Minimum |
200% | 5 Second Maximum |
Agency Information
• UR(UL) Recognition File: E19180
Environmental Data
• Operating temperature: -55°C to 125°C
• Mechanical shock: MIL-STD-202, Method 213
• High frequency vibration: MIL-STD-202, Method 204
• Load humidity: MIL-STD-202, Method 103
• Moisture resistance: MIL-STD-202, Method 106
• Resistance to solvents: MIL-STD-202, Method 215
• Thermal shock: MIL-STD-202, Method 107
Ordering
• Specify packaging and product code
(i.e., TR2/6125FF500-R)
Soldering Method
• Wave immersion: 260°C, 10 Sec. max.
• Solder reflow: 260°C, 30 Sec. max.
Dimensions - mm (in)
Specifications
Time-Current Curve
Dimensions - mm (in)
Specifications
Part Number |
Current Rating (amps) |
Voltage Rating |
Interrupting Rating (amps) |
DC Cold Resistance (mΩ) Typ. |
Melting I2t (A2 sec) |
Typical Voltage Drop (mV) | |||
Vac | Vdc | 125Vac | 72Vdc | 32Vdc | |||||
6125FF500-R | 500mA | 125 | 72 | 50 | 50 | 300 | 750 | 0.08 | 605 |
6125FF750-R | 750mA | 125 | 72 | 50 | 50 | 300 | 350 | 0.152 | 433 |
6125FF1-R | 1A | 125 | 72 | 50 | 50 | 300 | 260 | 0.22 | 415 |
6125FF1.25-R | 1.25A | 125 | 72 | 50 | 50 | 300 | 171 | 0.355 | 410 |
6125FF1.5-R | 1.5A | 125 | 72 | 50 | 50 | 300 | 112 | 0.456 | 365 |
6125FF2-R | 2A | 125 | 72 | 50 | 50 | 300 | 49 | 1.67 | 160 |
6125FF2.5-R | 2.5A | 125 | 72 | 50 | 50 | 300 | 45 | 5.20 | 155 |
6125FF3-R | 3A | 125 | 72 | 50 | 50 | 300 | 35 | 6.24 | 153 |
6125FF3.5-R | 3.5A | 125 | 72 | 50 | 50 | 300 | 27 | 7.28 | 150 |
6125FF4-R | 4A | 125 | 72 | 50 | 50 | 300 | 26 | 7.4 | 145 |
6125FF5-R | 5A | 125 | 72 | 50 | 50 | 300 | 17 | 9.5 | 141 |
6125FF6.3-R | 6.3A | 125 | 72 | 50 | 50 | 300 | 14 | 15.1 | 135 |
6125FF7-R | 7A | 125 | 72 | 50 | 50 | 300 | 11 | 37.25 | 112 |
6125FF8-R | 8A | 125 | 72 | 50 | 50 | 300 | 8.7 | 70 | 110 |
6125FF10-R | 10A | 125 | 72 | 50 | 50 | 300 | 7.3 | 67.75 | 110 |
6125FF12-R | 12A | 125 | 72 | 50 | 50 | 300 | 5.3 | 210.59 | 106 |
6125FF15-R | 15A | 125 | 72 | 50 | 50 | 300 | 4.2 | 296.10 | 104 |
* AC Interrupting Rating (Measured at designated voltage, 100% power factor); DC Interrupting Rating (Measured at designated voltage, time constant of less than 50
microseconds, battery source)
** Typical Melting I2
t (Measured at 72Vdc, 10X rated current (not exceed 50A - IR @ 72Vdc)
Time-Current Curve
Packaging Code
Packaging Code Prefix | Description |
TR2 | 5,000 fuses on tape-and-reel on a 13 inch (330mm) reel |
总机: 0755-82862885, 82862629
传真: 总机 转 801
邮箱: service@bussmann.net.cn
网址: http://www.bussmann.net.cn
资料中心: http://bm-bussmann.com